| F300E1019 & F300A1625
PARTS |
|
|
 |
|
|
 |
 |
 |
Order parts
based on your model number. The F300 model
number is located on the inside of the door.
Otherwise order parts based on the
overall size of your cells. The F300 come in 5
sizes: The smalest model has one cell 12½ x
20. | |
 | |
 |
The two cell
models are 16 x 20, 16 x 25, 20 x 20, 20 x 25
inch.
The difference between the F300E and
F300A is the post-filter is not included with the
F300A. The F300A has the postfilter slot and a
postfilter only needs to be slid in. The F300B is
a 240v version of the 12½ x 20 F300A..
The
F300 is identical to the F50F but a different
paint color. |
 | |
 |
 |
|
|
|
|
|
|
|
|
|
|
 |
Your problem
is: The neon indicator
light is not coming on The
cells never spark Power box
switch is ON Door is tight in
place Blower is ON |
- Verify
Power is Present.
Unplug the power box
cord and operate a drop-light in the 3-prong
receptacle verifying an acceptable voltage and
current.
- Check
for Shorted Cells
A shorted cell can
prevent the indicator light from coming on.
Remove both cells, with door back in place
operate without cells. If the unit now appears
OK with indicator light ON, then the cells have
a problem.
- Operate without cells
- Check cells for broken wires
- Check cells for bent plates
- Check with one cell at a time (align cell
with contacts)
- Replace
or Repair Power Box.
If the power box is
plugged in to 120v and the Neon indicator still
does not light without the cells, then the
problem is in the power box.
- Check the on/off switch, interlock door
switch and wiring.
- Bypass the Air Flow Switch (AFS), The AFS
is a sensor that signals the power supply when
air flow is present. Disabling the AFS will
simulate the ON state. Using a jumper wire,
ground AFS resistor to the chassis, see AFS
Tech Notes.
- Replace Air Flow Switch, if the Neon
indicator lights and unit appears to work with
the AFS disabled.
- Replace Power Supply, if the Neon
indicator does not light with the AFS disabled
and no cells to short the output.
- Neon problem, is not likely if test
button does not spark. The neon lamp voltage
should measure 125 vdc.
| |
|
|