Honeywell F52F Parts Buy a New F52

No Description F52F1048
F52F1006
20 x 12½
F52F1055
F52F1014
20 x 25
1 Prefilter 208536 208537
2 Door / Grille (Egg Crate) 32001438-004 32001438-005
3 Electronic Cell FC37A1171 FC37A1171
4 Airflow Switch 4074ETH 4074ETH
6 Cell Contact Board 4074EHG 4074EHG
7 Cabinet Contact Board 190912A 190912A
8 On-Off Switch 203321 203321
9 Interlock Switch (120v) 208543 208543
10 Power Supply 120v - Series 1
Series 2 (1998 & later)
208427J
208416AB
208427AA
208416AA
13 Neon Assembly 4074ETE 4074ETE
14 Cell Handle 137266 137266
15 Cell Ionizer Wire 136434AA 136434AA
16 High Voltage Wire
Red & Black
4074EMN
4074EMP
4074EMN
4074EMP

This parts drawing is from the F52F Product Data Manual.
Ionizer Wire (20 inch 136434AA) Cell Handle (137266) Prefilter (208536) Prefilter (208537) Door / Grille (Egg Crate 32001438-004) Door / Grille (Egg Crate 32001438-005) Electronic Cell (FC37A1171) Electronic Cell (FC37A1171) Electronic Cell (FC37A1171) Air Flow Switch (4074ETH) Air Flow Switch (4074ETH) Air Flow Switch (4074ETH) Air Flow Switch (4074ETH) Cell Contact Board (4074EHG) Cell Contact Board (4074EHG) Cabinet Contact Board (190912A) Cabinet Contact Board (190912A) On-Off Switch (203321) On-Off Switch (203321) Interlock Switch (208543) Interlock Switch (208543) Power Supply (Series 1 or 2) Power Supply (Series 1 or 2) Neon Lamp Assembly (4074ETE) Neon Lamp Assembly (4074ETE) High Voltage Wire

Where is my model number ?

The model number label is located behind the grille on the power supply enclosure (part ). Such as F52F1055.

Series 1 or 2 Power supplies manufactured in 1998 or later use a power supply compatible with the new W8600F remote performance indicator. (143k pdf, 2 photos)

Repair Help

See the Troubleshooting section in the F52F Product Data starting at page 12.

Basic Power Supply Test Procedure
Your indicator light is not coming on 13
Grille is tight in place or Interlock switch is closed  9 
Power box switch is ON  8 
Unit never sparks
Blower is ON
  1. Verify Power is Present.
    Check for 120v at power supply terminals P1 and P2 using a meter or test light.
  2. Check for Shorted Cells (part  3 ).
    A shorted cell can prevent the indicator light from coming on. Remove cell(s), with door back in place operate without cell(s). If the unit now appears OK with indicator light ON, then there is a cell problem.
    1. Operate without cell(s)
    2. Check cells for broken wires
    3. Check cells for bent plates
    4. Check with one cell at a time (align cell with contacts)
  3. Check Power Supply and Air Flow Switch (part 10 and  4 ).
    The power supply has 120v at input and the Neon indicator still does not light without the cells.
    1. Bypass the Air Flow Switch (AFS)  4 , The AFS is a sensor that signals the power supply when air flow is present. Disabling the AFS will simulate the ON state. Using a jumper wire, ground AFS resistor to the chassis, see AFS Tech Notes.
      • Replace Air Flow Switch  4 , if the Neon indicator lights and unit appears to work with the AFS disabled. 1994 AFS instructions
      • Replace Power Supply 10, if the Neon indicator does not light with the AFS disabled and no cells to short the output. Spark Test
      • Neon problem 13, is not likely if unit does not spark. The neon lamp voltage measures 125 vdc.
 

F52F Repair Manual (print and save)

F52F Product Data Troubleshooting flowchart, assembly drawing, exploded view, parts list. Troubleshooting starts at page 12. (990k pdf, 20 pages)
Manuals have Troubleshooting Flowchart

Cross Reference

Cross Reference Lookup part numbers with your model number. Part numbers for power supply and power box. (70k pdf, 2 pages)

Power Supply

Power Supply 208427 Installation Instructions for Replacement Kit 208427(AA-Z). Cross Reference Table, Troubleshooting, Wiring Diagrams, Warranty. (323k pdf)
Tech note has photos of power box
Series 2 Upgrade Tech Notes Early (1994) F50F power supplies 203101 used individual post connectors for each wire, new power supplies have modular connectors but also have posts for retrofit. (742k pdf, 3 pages)

Air Flow Switch

AFS Tech Notes How it works, shorting resistor to override AFS, voltage measurements, dimensions. (81k pdf, 2 pages)
Tech Note on testing Air Flow Switch
202121A AFS Installation Instructions included with Air Flow Switch 202121a. The 202121a is obsolete, for reference only. (139k pdf, 1 page)

Cell Maintenance and Repair

F52F Product Data Manual Replacing ionizing wires, see page 11. Cell cleaning, page 10. Ohmmeter test page 15.

4074EHG Repair Instruction Replacing contact board assembly 4074EHG (123k pdf, 2 pages)

4074EHG Cell Repair Kit

Part Number Search

 
  Enter a part number:   

  Results may list replacement part numbers.

Electronic Air Cleaner Categories
Duct Mount
Return Grille
Ceiling
Portable
Parts

Cleaning
Aprilaire
Emerson
Electro-Air

Honeywell
Trion
Emerson
Honeywell
Trion
Emerson
Honeywell
Trion
Emerson
Friedrich
Emerson
Electro-Air

Honeywell
Emerson
Nu-Calgon

  
More Honeywell Products

Honeywell
Parts


Honeywell
Duct Mount


Honeywell
Return Grille


Honeywell
Ceiling


Honeywell
Media Filters


Honeywell
Humidifiers


Honeywell
Ultra-Violet