F52F Genuine Electronic Air Cleaner Parts
|
|
| Honeywell F52F Parts |
Buy a New F52 | |
Repair Help
See the Troubleshooting section in the
F52F Product Data
starting at page 12.
|
Basic Power Supply Test Procedure
|
Your indicator light is not coming on 13
Grille is tight in place or Interlock switch is closed 9
Power box switch is ON 8
Unit never sparks
Blower is ON
|
-
Verify Power is Present.
Check for 120v at power supply terminals P1 and P2 using a meter or test light.
-
Check for Shorted Cells
(part 3 ).
A shorted cell can prevent the indicator light from coming on.
Remove cell(s), with door back in place operate without cell(s).
If the unit now appears OK with indicator light ON, then there is a cell problem.
-
Operate without cell(s)
-
Check cells for broken wires
-
Check cells for bent plates
-
Check with one cell at a time (align cell with contacts)
-
Check Power Supply and Air Flow Switch
(part 10 and 4 ).
The power supply has 120v at input and the Neon indicator still does not light without the cells.
-
Bypass the Air Flow Switch (AFS) 4 ,
The AFS is a sensor that signals the power supply when air flow is present.
Disabling the AFS will simulate the ON state. Using a jumper wire, ground AFS resistor to the chassis, see
AFS Tech Notes.
-
Replace Air Flow Switch 4 ,
if the Neon indicator lights and unit appears to work with the AFS disabled.
1994 AFS instructions
-
Replace Power Supply 10,
if the Neon indicator does not light with the AFS disabled and no cells to short the output.
Spark Test
-
Neon problem 13,
is not likely if unit does not spark. The neon lamp voltage measures 125 vdc.
|
|
|
F52F Repair Manual (print and save)
F52F Product Data
Troubleshooting flowchart, assembly drawing, exploded view, parts list. Troubleshooting starts at page 12. (990k pdf, 20 pages)
|
|
Cross Reference
Cross Reference
Lookup part numbers with your model number.
Part numbers for power supply and power box. (70k pdf, 2 pages)
Power Supply
Power Supply 208427 Installation
Instructions for Replacement Kit 208427(AA-Z). Cross Reference Table, Troubleshooting, Wiring Diagrams, Warranty. (323k pdf)
|
|
Series 2 Upgrade Tech Notes
Early (1994) F50F power supplies 203101 used individual post connectors for each wire, new power supplies have modular connectors but also have posts for retrofit. (742k pdf, 3 pages)
Air Flow Switch
AFS Tech Notes
How it works, shorting resistor to override AFS, voltage measurements, dimensions. (81k pdf, 2 pages)
|
|
202121A AFS Installation
Instructions included with Air Flow Switch 202121a. The 202121a is obsolete, for reference only. (139k pdf, 1 page)
Cell Maintenance and Repair
| |
| Electronic Air Cleaner Categories |
|
|
|